CASE NO: 053
OBJECT: | Grind oversize agglomerations in hazardous waste incinerator liquid feed burner nozzle. | PROBLEM: | Lumpy material plugs 1/8” burner nozzles - - in-line strainers fill up and operators have to open to air and clean. | RESULTS: | Incinerator runs for over one month on same burner nozzle. Strainers no longer required. | AB MIXER: | Model 3 x 1.5 7.5 HP, 3/16” discharge grid | EQUIPMENT REPLACED | In-line strainers. |
|
|